SD240GS with ADA Accessible Means of Egress

U.S. Smoke & FireFire Protective Smoke Curtains › SD240GS Smoke Curtain with ADA Accessible Means of Egress

U.S. Smoke & Fire – SD240GS 2-3 Hr Fire Protective Smoke Curtain with Pass Through Slot is a smoke and fire barrier system per IBC 1008. UL certified for up to 3 hours. Utilized for corridor rating, cross corridor solutions where push to exit is required.

 

Technical Information:

  • UL certified for up to 3 hours.
  • The curtain can have a maximum span up to 146 feet and drop height of 45 feet.
  • Utilized for corridor rating, cross corridor solutions where push to exit is required.
  • Push to exit is less than 15 pounds of push force.
  • Threshold is 3/4 inch.
  • The slope is 50%.
  • The opening is more than six foot, eight inches from the top.
  • Pass through slot

Product Downloads:

SEE THE SMOKE CURTAIN IN ACTION:

VIEW IMAGES OF THE SMOKE CURTAIN IN ACTION:

 

View Additional Products Below:

SD60GS 1HR Smoke Curtain System With Egress
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60GS...
Learn More
SD240GS 2 Hr Fire Protective Smoke Curtain
U.S. Smoke & Fire ›Fire Protective Smoke Curtains...
Learn More
SD240GS 2 Hr with Pass Through Slot Egress
U.S. Smoke & Fire ›Fire Protective Smoke Curtains...
Learn More
SD240A 3 Hr Accordion for Corner Conditions with Egress
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD240A...
Learn More
ESC Magnetic Seal Curtains for Elevator
U.S. Smoke & Fire › Fire Protective Smoke Curtains › ESC Magnetic Seal...
Learn More
Hose Stream 180 Fire Protection Shutter
U.S. Smoke & Fire Hose Stream 180 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a two hour fire rated wall assembly. Please see below IBC TABLE...
Learn More
Hose Stream 120 Horizontal Fire Protection Shutter
TESTED FOR 120 MINUTES FIRE PROTECTION RATING WHEN TESTED IN ACCORDANCE WITH UL 10B STANDARD WITH HOSE STREAM TEST (ASTM E2226) Hose Stream 120 Horizontal Fire Shutter is utilized to enclose a floor opening for continuity of rating....
Learn More
Hose Stream 120 First Responder Fire Protection Shutter
U.S. Smoke & Fire Hose Stream 120 FIRST RESPONDER Steel-Tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two-hour fire rated wall or fire barrier...
Learn More
SD60GS Elevator Smoke Containment System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60GS...
Learn More
SD60 FIXED FABRIC DRAFT CURTAIN
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60...
Learn More
SD60 Deployable Draft Curtain UL Listed System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60 Deployable Draft Curtain U.S. Smoke & Fire... Deployable Draft Curtain Automatically Descends And Retracts Out Of View From The End User. The...
Learn More
SD60 Smoke Curtain UL Listed System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60 Smoke...
Learn More
Hose Stream 120 Fire Protection Shutter
U.S. Smoke & Fire Hose Stream 120 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two hour fire rated wall assembly. Please see below IBC...
Learn More
Dual Hose Stream 120 UL Certified Fire Protection Shutters
  U.S. SMOKE & FIRE DUAL HOSE STREAM 120 WHEN 25% OF THE OPENING IN A FIREWALL IS EXCEEDED THEN AN ASTM E119 (UL 263) LISTED AND LABELED ASSEMBLY IS REQUIRED IN COMPLIANCE WITH IBC SECTION 707.6 EXCEPTION 3. THE DUAL CURTAIN IS TESTED...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640