Hose Stream 120 Fire Protection Shutter

U.S. Smoke & Fire Hose Stream 120 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two hour fire rated wall assembly.
Please see below IBC TABLE OPENING FIRE PROTECTION ASSEMBLIES

The U.S. Smoke & Fire Hose Stream 120 shutter is tested to UL 10B and has a minimum of 1 1/2 hour fire protection rating to be sufficient for an opening protective in a 2- hour fire barrier enclosing wall per IBC Table. A hose stream test (ASTM E2226) is conducted as part of the fire endurance testing and the shutter shall have passed this test.
The head-box is mounted utilizing threaded rods and unistruts. For power, 120V to motor side of the head-box. The Steel-Tex Fire Shutter (SFS) will release when receiving a signal from fire alarm system (FAS). Push to exit buttons are installed for egress. Leading edge safety sensor option. BMS relay option. Beam Sensor option.
Hose Stream 120 Installed Back to Back
Please note that two systems each with a fire protection rating of 1 1/2 hour, installed on opposing sides of the same opening in a fire wall, shall be deemed equivalent in fire protection rating to one 3-hour system per IBC table a.- Harmathy's Principle

Product Downloads For HOSE STREAM 120:

PRODUCT DOWNLOADS FOR HOSE STREAM 120 INSTALLED BACK TO BACK FOR 90 MINUTES EACH (3 HOURS BY HARMATHY PRINCIPLE)

SD60GS 1HR Smoke Curtain System With Egress
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60GS...
Learn More
SD240GS 2 Hr Fire Protective Smoke Curtain
U.S. Smoke & Fire ›Fire Protective Smoke Curtains...
Learn More
SD240GS 2 Hr with Pass Through Slot Egress
U.S. Smoke & Fire ›Fire Protective Smoke Curtains...
Learn More
SD240A 3 Hr Accordion for Corner Conditions with Egress
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD240A...
Learn More
ESC Magnetic Seal Curtains for Elevator
U.S. Smoke & Fire › Fire Protective Smoke Curtains › ESC Magnetic Seal...
Learn More
Hose Stream 180 Fire Protection Shutter
U.S. Smoke & Fire Hose Stream 180 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 3 hour fire protection rating and therefore can be used in a two hour fire rated wall assembly. Please see below IBC TABLE...
Learn More
Hose Stream 120 Horizontal Fire Protection Shutter
TESTED FOR 120 MINUTES FIRE PROTECTION RATING WHEN TESTED IN ACCORDANCE WITH UL 10B STANDARD WITH HOSE STREAM TEST (ASTM E2226) Hose Stream 120 Horizontal Fire Shutter is utilized to enclose a floor opening for continuity of rating....
Learn More
Hose Stream 120 First Responder Fire Protection Shutter
U.S. Smoke & Fire Hose Stream 120 FIRST RESPONDER Steel-Tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two-hour fire rated wall or fire barrier...
Learn More
SD240GS with ADA Accessible Means of Egress
U.S. Smoke & Fire Hose Stream 120 FIRST RESPONDER Steel-Tex Fire Shutter (SFS)...
Learn More
SD60GS Elevator Smoke Containment System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60GS...
Learn More
SD60 FIXED FABRIC DRAFT CURTAIN
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60...
Learn More
SD60 Deployable Draft Curtain UL Listed System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60 Deployable Draft Curtain U.S. Smoke & Fire... Deployable Draft Curtain Automatically Descends And Retracts Out Of View From The End User. The...
Learn More
SD60 Smoke Curtain UL Listed System
U.S. Smoke & Fire › Fire Protective Smoke Curtains › SD60 Smoke...
Learn More
Dual Hose Stream 120 UL Certified Fire Protection Shutters
  U.S. SMOKE & FIRE DUAL HOSE STREAM 120 WHEN 25% OF THE OPENING IN A FIREWALL IS EXCEEDED THEN AN ASTM E119 (UL 263) LISTED AND LABELED ASSEMBLY IS REQUIRED IN COMPLIANCE WITH IBC SECTION 707.6 EXCEPTION 3. THE DUAL CURTAIN IS TESTED...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640