Make U.S. Smoke & Fire your Basis of Design
UL Listed, UL Labeled, UL Certified, UL Recognized Fire protective smoke curtains (File# R26410)

SD60 Deployable Draft Curtain UL Listed System

U.S. Smoke & Fire Fire Protective Smoke Curtains SD60 Deployable Draft Curtain

SD60 Deployable Draft Curtain - 143014345601

U.S. Smoke & Fire...

Deployable Draft Curtain Automatically Descends And Retracts Out Of View From The End User.

SD60 Deployable Draft Curtain - Smoke-Baffle

The Competition...

All Glass Draft Baffles Fixed In Place. Always Visible To The End User.

The U.S. Smoke & Fire -- SD60 Deployable Draft Curtain is a UL Listed, Labeled, and Recognized GRAVITY FAIL SAFE deployable automatic smoke draft curtain that provides channeling of smoke from open stairwells, escalator openings, and other floor openings.

Technical Information:

  • 1 hour smoke and fire curtain.
  • A single or multi- roller assembly with a 0.05 in. thick galvanized steel head box with a minimum 5.9 in. x 5.9 in. with a maximum span up to 60 ft. and drop height of 45 ft.
  • A 24 V motor control circuit (MCC) housed the steel enclosure and mounted onto the motor end of the head box.
  • Removable fire rated cover plates incorporated to allow access to curtain rollers.

Product Downloads:

SEE THE DEPLOYABLE CURTAINS IN ACTION:

Why Choose Fire Protective Smoke Curtains for Your Open Floor Plan?
  • Rated as for 1 hour, 2 hours and 3 hour smoke and fire partition, barrier and opening protective.
  • Only a 7 inch by 7 inch housing for up to a 18 feet length with a 10 feet drop height.
  • Housings of 7 inch by 11 inches for lengths longer than 19 feet.
  • Typical 60 feet length curtain housing with 40 foot drop only 8 inches by 13 inches.
  • Accordion smoke and fire barrier systems makes turns and angles without posts and rails.
  • Gravity Fail Safe Deployment.
  • Fully Integrates with Fire Alarm System with optional building management system relay per UL 864.
  • Report holder for Elevator smoke containment and elevator lobby smoke containment per ICC AC-77.
  • Utilized to Rate Corridor in lieu of fire rated glass, washing glass In lieu of horizontal accordion doors and cross corridor area separation with pass through egress.
  • Enclose monumental stairways and secondary Egress paths makes fixed glass draft curtains a thing of the past.
  • Curtains with redundant forms of egress, pass through egress, rewind switches, two stage descents, delayed descents.
  • Curtains used for stages per NFPA 80 guidelines.
  • Restricts Atrium Volume as part of an Atrium Smoke Management System per IBC 909 and IBC 404.5 exception 3.
  • Provides Atrium Separation per IBC 404.5 Exception 6 back to 2 floor rule for removal of smoke management system.
  • Horizontal Curtains to separate two floors allows architects to design more open floor plans.
It's not just what we make,
it's what we make possible.
Dr Steven S. Sadeghian CEO, U.S. Smoke & Fire