Hose Stream 120 Fire Protection Shutter

U.S. Smoke & Fire Hose Stream 120 Steel-tex Fire Shutter (SFS) is an opening protective that meets the requirement for a 90- minute fire protection rating and therefore can be used in a two hour fire rated wall assembly.
Please see below IBC TABLE OPENING FIRE PROTECTION ASSEMBLIES

The U.S. Smoke & Fire Hose Stream 120 shutter is tested to UL 10B and has a minimum of 1 1/2 hour fire protection rating to be sufficient for an opening protective in a 2- hour fire barrier enclosing wall per IBC Table. A hose stream test (ASTM E2226) is conducted as part of the fire endurance testing and the shutter shall have passed this test.
The head-box is mounted utilizing threaded rods and unistruts. For power, 120V to motor side of the head-box. The Steel-Tex Fire Shutter (SFS) will release when receiving a signal from fire alarm system (FAS). Push to exit buttons are installed for egress. Leading edge safety sensor option. BMS relay option. Beam Sensor option.
Hose Stream 120 Installed Back to Back
Please note that two systems each with a fire protection rating of 1 1/2 hour, installed on opposing sides of the same opening in a fire wall, shall be deemed equivalent in fire protection rating to one 3-hour system per IBC table a.- Harmathy's Principle

Product Downloads For HOSE STREAM 120:

PRODUCT DOWNLOADS FOR HOSE STREAM 120 INSTALLED BACK TO BACK FOR 90 MINUTES EACH (3 HOURS BY HARMATHY PRINCIPLE)

Multi-Level Atriums: Smoke & Fire Curtain Applications
Smoke curtains reduce the make-up air requirements and channel and...
Learn More
Museums: Smoke & Fire Curtain Applications
Museums constructed in the last 50 years have drifted away from...
Learn More
Metro Stations: Smoke & Fire Curtain Applications
Metro Stations are mission critical facilities that must continue operation...
Learn More
Escalators & Stairs: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications for Escalators & Stairs is a...
Learn More
Historic Buildings: Smoke & Fire Curtain Applications
Whether it is the renovation of Montpelier, or the updating of...
Learn More
Prison & Detention Centers: Smoke & Fire Curtain Applications
Prisons and detention facilities are a particularly daunting design...
Learn More
Airports: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Airports are a...
Learn More
High Rise Hotels & Condominiums: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications Provide Added Safety for High...
Learn More
Terrorist Threats: Smoke & Fire Curtain Applications
Mission critical structures, such as ports, nerve centers, power...
Learn More
Elevators: Smoke & Fire Curtain Applications
Smoke & Fire Curtain Applications in Elevators Play an Important...
Learn More
Stages & Auditoriums: Smoke & Fire Curtain Applications
Our smoke curtains are readily applied to the needs of custom-made...
Learn More

The UL trademark is a registered trademark of Underwriters Laboratories.

866-204-8640