Airports: Smoke & Fire Curtain Applications

Smoke & Fire Curtain Applications in Airports are a Necessity

Airport fires pose a serious threat to safety in airport concourses. Airport fires have occurred at Ataturk Airport in Istanbul, Manchester Airport, and Amsterdam's Schiphol Airport where significant loss of life occurred.

The FAA considers airport fires significant enough that they require special fire brigades to be deployed at airports of a certain size and flight frequency.

Air Traffic Control Centers must also be protected during these events to prevent catastrophe in the air. U.S. Smoke & Fire effectively keeps air traffic control online by:

  • Providing the Control Tower with a fire and smoke safe haven for up to 2 hours. Fire and smoke curtains can be deployed to effectively create walls, forming a safe room, and buying critical time for controllers.
  • Curtains can be both automatically and manually deployed.
  • These systems integrate with existing fire alarm systems.
  • Curtain technology provides for easy exit, in that they are egress safe through the use of an exit button. Further, the curtain materials are light-weight and hand liftable.
  • Concourses

In large open areas smoke curtains and a smoke extraction system are optimized when used in conjunction with the smoke curtains. This combination of curtain technology enables three significant safety features:

  • Smoke is routed away from people and merchandise to the extraction system.
  • The extraction system removes the smoke and toxins from the facility.
  • The smoke curtain provides an effective block for smoke and fire. People have time to leave, and fire personnel are able to easily enter.

Concourses are also often served by escalators and trams. Deploying curtains along escalators and tram routes provides a safe path for egress, as well as ingress for emergency personnel. Further, in the event that the main power or back-up generator fails, the smoke curtain will operate independently and deploy as directed by the alarm system. Should the alarm panel be compromised, the fail-safe design will still deploy the curtains. Deployable Draft Curtains can also be utilized in lieu of the 18" glass. This allows for cleaner site lines and an invisible solution.

 

View Additional Applications Below:

Why Choose Fire Protective Smoke Curtains for Your Open Floor Plan?
  • Rated as for 1 hour, 2 hours and 3 hour smoke and fire partition, barrier and opening protective.
  • Only a 7 inch by 7 inch housing for up to a 18 feet length with a 10 feet drop height.
  • Housings of 7 inch by 11 inches for lengths longer than 19 feet.
  • Typical 60 feet length curtain housing with 40 foot drop only 8 inches by 13 inches.
  • Accordion smoke and fire barrier systems makes turns and angles without posts and rails.
  • Gravity Fail Safe Deployment.
  • Fully Integrates with Fire Alarm System with optional building management system relay per UL 864.
  • Report holder for Elevator smoke containment and elevator lobby smoke containment per ICC AC-77.
  • Utilized to Rate Corridor in lieu of fire rated glass, washing glass In lieu of horizontal accordion doors and cross corridor area separation with pass through egress.
  • Enclose monumental stairways and secondary Egress paths makes fixed glass draft curtains a thing of the past.
  • Curtains with redundant forms of egress, pass through egress, rewind switches, two stage descents, delayed descents.
  • Curtains used for stages per NFPA 80 guidelines.
  • Restricts Atrium Volume as part of an Atrium Smoke Management System per IBC 909 and IBC 404.5 exception 3.
  • Provides Atrium Separation per IBC 404.5 Exception 6 back to 2 floor rule for removal of smoke management system.
  • Horizontal Curtains to separate two floors allows architects to design more open floor plans.